Health & Safety

Health and safety practices are those that set standards for conditions supporting the physical and mental wellbeing of workers or inhabitants. This often takes the form of hazard prevention—for example, in workplaces where useful but potentially harmful chemicals can pose a danger if mismanaged (e.g. corrosive, flammable, etc.). Depending on industry and research, rules or regulations may dictate concentration limits or handling practices for compounds such as ammonia (NH3), hydrogen chloride (HCl), or hydrogen fluoride (HF). Monitoring typically takes place via onsite real-time measurements.

Analyzers

Product Model Measurements

G2108 Gas Concentration Analyzer

The Picarro G2108 gas concentration analyzer provides precise, real-time measurement of hydrogen chloride (HCl) and water (H2O) vapor at parts-per-trillion (ppt) sensitivity with negligible drift for atmospheric science and air quality applications.

G2108

G2204 Gas Concentration Analyzer

The Picarro G2204 gas concentration analyzer provides simultaneous, precise measurement of methane (CH4) and hydrogen sulfide (H2S) at parts-per-billion (ppb) sensitivity with negligible drift for emissions measurements from landfills, refineries, paper mills, or industrial plants.

G2204

G2205 Gas Concentration Analyzer

The Picarro G2205 gas concentration analyzer provides precise, real-time measurement of hydrogen fluoride (HF) and water (H2O) vapor at parts-per-trillion (ppt) sensitivity with negligible drift for atmospheric science and air quality applications.

G2205

G2307 Gas Concentration Analyzer

The Picarro G2307 gas concentration analyzer provides precise, real-time measurement of formaldehyde (H2CO), methane (CH4), and water (H2O) vapor.

G2307

G2910 Gas Concentration Analyzer

Within Picarro’s family of Ethylene Oxide (EtO) gas concentration analyzers, the G2910 Stack and Indoor Air Quality Analyzer has been configured to enable measurements of EtO at the source of emission. The G2910 supports measurements over a broad range of EtO concentrations, with support for complex gas mixtures, without sacrificing precision and stability. In applications where accurate, real-time quantification of EtO emissions is required, Picarro excels over traditional technologies, such as Fourier-Transform Infrared Spectroscopy (FTIR) or Gas Chromatography (GC). Quantification of EtO from stacks, abatement systems, sterilization rooms, aeration warehouses and building ventilation has never been easier.
G2910

G2920 Gas Concentration Analyzer

Within Picarro’s family of Ethylene Oxide (EtO) gas concentration analyzers, the G2920 Ambient Analyzer introduces a platform that supports long-term monitoring of fugitive emissions at the fenceline and ambient concentrations of EtO near communities. In applications where accurate, real-time quantification of EtO emissions is required, Picarro excels over traditional technologies, such as Fourier-Transform Infrared Spectroscopy (FTIR) or Gas Chromatography (GC). Quantification of fugitive EtO emissions from industrial facilities has never been easier.

G2920

Peripherals

Product Model Measurements

Ambient Air Monitoring System for Ethylene Oxide

The ability to monitor and quantify ethylene oxide (EtO or EO) is central to eliminating sources and reducing long-term exposure to this hazardous air pollutant. The Picarro Ambient Air Monitoring System for Ethylene Oxide continuously and automatically monitors and quantifies low, ambient levels of EtO. It is ideal for use in community monitoring stations and at industrial fencelines. 

Leveraging Picarro’s advanced Cavity Ring-Down Spectroscopy (CRDS), this system offers several unique advantages over canister-based methods and legacy technologies, including: 

16-Port Distribution Manifold

The Picarro 16-Port Distribution Manifold provides unparalleled multiport sample-data collection.

A0311

Small Sample Introduction Module 2

High-precision δ13C measurements of small volume CO2 and CH4 gas samples.

A0314