Company Logo

Languages

  • 简体中文
  • English
About Picarro | Contact Us | Newsletter | Contact Us | Login
  • Markets Served
    • Greenhouse Gas Measurements
    • Carbon Isotope Measurements
    • Water Isotope Measurements
    • Natural Gas Industry
    • Food Traceability and Security
    • Industrial Gas Monitoring
  • Gas Analyzers
    • Gas Analyzers
    • CH4 and C2H2
    • CO CO2 CH4 H2O
    • Flight CO CO2 CH4 H2O
    • CH4 and H2S
    • CO2 CH4 H2O
    • Fast CO2 CH4 H2O for EC Flux
    • Flight CO2 CH4 H2O
    • CO CO2 H2O
    • Ammonia
    • Hydrogen Fluoride
    • Hydrogen Peroxide
    • Formaldehyde
    • Ethylene
    • Peripherals
    • N2O
  • Isotope Analyzers
    • Isotope Analyzers
    • H2O Isotopes — Solids, Liquids, and Vapor
    • 13C+D CM-CRDS
    • δ13C of CH4 CO2
    • IM-CRDS System for Isotopic Water Analysis
    • δ13C of CO2
    • δ13C of CH4
    • 13C CM-CRDS
    • iTOC-CRDS
    • N2O Isotopes
    • Peripherals
  • Services
    • Service, Parts, and Consumables
    • Instrument Performance Package (IPP)
    • Technical Jumpstart Program
    • Health Check Program
    • Factory Refresh Program
    • Analyzer Supplies
  • Help/Resources
    • Open Tech Support Ticket
    • Instrument Performance VerificationTM
    • Literature by Application
    • Knowledgebase
    • Application Notes
    • Literature & Publications
    • Datasheets
    • Customer Conference Posters
    • Conference Presentations
    • Webcasts and Webinars
    • Whitepapers
    • Get a Quote
  • Technology
    • Why CRDS
    • What is CRDS
    • Analyzer Performance & Advantages
    • Comparison to Other Trace Gas Analyzers
    • Software Innovation From Picarro
    • Instrument Performance VerificationTM
    • Technical Addendum
    • FAQs
  • Community
    • Picarro Community
    • Knowledgebase
    • Picarro Blog
  • Open Tech Support Ticket
  • Instrument Performance VerificationTM
  • Literature by Application
  • Knowledgebase
  • Application Notes
  • Literature & Publications
  • Datasheets
  • Customer Conference Posters
  • Conference Presentations
  • Webcasts and Webinars
  • Whitepapers
  • Get a Quote

Work at Picarro

Water Vapor Correction for the G2101-i Isotopic CO2 Analyzer

Water Vapor Correction for the G2101-<em>i</em> Isotopic CO<sub>2</sub> Analyzer
Home › Resources › Whitepapers › Water Vapor Correction for the G2101-i Isotopic CO2 Analyzer

Water Vapor Correction for the G2101-i Isotopic CO2 Analyzer

A novel methodology and software tool to automatically correct for water vapors and eliminate the need to use gas drying equipment for isotopic CO2 sampling. 

Abstract: 

The Picarro G1101-i and G2101-i gas analyzers provide field measurements of the stable isotope ratio 13CO2 with a precision of 0.3 permil in five minutes. In an isotope ratio mass spectrometry (IRMS) laboratory, it is customary to dry the samples to very low dew points (< - 45C) prior to isotope analysis. For field work, however, drying the samples is in many cases inconvenient or impractical. Water vapor can affect the reported delta via spectroscopic broadening or direct spectroscopic interference. In the G2101-i, the effects of the water vapor concentration, including its isotopes, has been characterized, and the reported isotope ratios have been corrected. Residual errors of less than 0.3 permil can be achieved in the G2101-i, even in very humid gas streams.

Download Now


  • © 2012 Picarro Inc.
  • Site Map
  • Privacy Policy
  • Terms of Service