Company Logo

Languages

  • 简体中文
  • English
About Picarro | Contact Us | Newsletter | Contact Us | Login
  • Markets Served
    • Greenhouse Gas Measurements
    • Carbon Isotope Measurements
    • Water Isotope Measurements
    • Natural Gas Industry
    • Food Traceability and Security
    • Industrial Gas Monitoring
  • Gas Analyzers
    • Gas Analyzers
    • CH4 and C2H2
    • CO CO2 CH4 H2O
    • Flight CO CO2 CH4 H2O
    • CH4 and H2S
    • CO2 CH4 H2O
    • Fast CO2 CH4 H2O for EC Flux
    • Flight CO2 CH4 H2O
    • CO CO2 H2O
    • Ammonia
    • Hydrogen Fluoride
    • Hydrogen Peroxide
    • Formaldehyde
    • Ethylene
    • Peripherals
    • N2O
  • Isotope Analyzers
    • Isotope Analyzers
    • H2O Isotopes — Solids, Liquids, and Vapor
    • 13C+D CM-CRDS
    • δ13C of CH4 CO2
    • IM-CRDS System for Isotopic Water Analysis
    • δ13C of CO2
    • δ13C of CH4
    • 13C CM-CRDS
    • iTOC-CRDS
    • N2O Isotopes
    • Peripherals
  • Services
    • Service, Parts, and Consumables
    • Instrument Performance Package (IPP)
    • Technical Jumpstart Program
    • Health Check Program
    • Factory Refresh Program
    • Analyzer Supplies
  • Help/Resources
    • Open Tech Support Ticket
    • Instrument Performance VerificationTM
    • Literature by Application
    • Knowledgebase
    • Application Notes
    • Literature & Publications
    • Datasheets
    • Customer Conference Posters
    • Conference Presentations
    • Webcasts and Webinars
    • Whitepapers
    • Get a Quote
  • Technology
    • Why CRDS
    • What is CRDS
    • Analyzer Performance & Advantages
    • Comparison to Other Trace Gas Analyzers
    • Software Innovation From Picarro
    • Instrument Performance VerificationTM
    • Technical Addendum
    • FAQs
  • Community
    • Picarro Community
    • Knowledgebase
    • Picarro Blog
  • Open Tech Support Ticket
  • Instrument Performance VerificationTM
  • Literature by Application
  • Knowledgebase
  • Application Notes
  • Literature & Publications
  • Datasheets
  • Customer Conference Posters
  • Conference Presentations
  • Webcasts and Webinars
  • Whitepapers
  • Get a Quote

Work at Picarro

Reduced drift, high accuracy stable carbon isotope ratio measurements using a reference gas with the Picarro G2101-i gas analyzer

Reduced drift, high accuracy stable carbon isotope ratio measurements using a reference gas with the Picarro G2101-<em>i</em> gas analyzer
Home › Resources › Whitepapers › Reduced drift, high accuracy stable carbon isotope ratio measurements using a reference gas with the Picarro G2101-i gas analyzer

Reduced drift, high accuracy stable carbon isotope ratio measurements using a reference gas with the Picarro G2101-i gas analyzer

A methodology and guide to further reducing the analzyer drift dramatically by referencing the measurements to a secondary or working gas standard. 

Abstract: 

The Picarro G2101-i gas analyzer provides exceptionally low drift measurements right out of the box, allowing field measurements of the stable isotope ratio 13CO2 with a precision of 0.3 permil in five minutes, and a drift of about 1-2 permil in a 24 hour period. For more demanding applications, it is possible to reduce the drift dramatically by referencing the measurements to a secondary or working gas standard. In this white paper we describe a method for employing a working standard to improve the measurement precision to below 0.1 permil. If the working standard is also traceable to a primary reference scale, this precision can translate into an overall accuracy of better than 0.1 permil.

Download Now


  • © 2012 Picarro Inc.