Company Logo

Languages

  • 简体中文
  • English
About Picarro | Contact Us | Newsletter | Contact Us | Login
  • Markets Served
    • Greenhouse Gas Measurements
    • Carbon Isotope Measurements
    • Water Isotope Measurements
    • Natural Gas Industry
    • Food Traceability and Security
    • Industrial Gas Monitoring
  • Gas Analyzers
    • Gas Analyzers
    • CH4 and C2H2
    • CO CO2 CH4 H2O
    • Flight CO CO2 CH4 H2O
    • CH4 and H2S
    • CO2 CH4 H2O
    • Fast CO2 CH4 H2O for EC Flux
    • Flight CO2 CH4 H2O
    • CO CO2 H2O
    • Ammonia
    • Hydrogen Fluoride
    • Hydrogen Peroxide
    • Formaldehyde
    • Ethylene
    • Peripherals
    • N2O
  • Isotope Analyzers
    • Isotope Analyzers
    • H2O Isotopes — Solids, Liquids, and Vapor
    • 13C+D CM-CRDS
    • δ13C of CH4 CO2
    • IM-CRDS System for Isotopic Water Analysis
    • δ13C of CO2
    • δ13C of CH4
    • 13C CM-CRDS
    • iTOC-CRDS
    • N2O Isotopes
    • Peripherals
  • Services
    • Service, Parts, and Consumables
    • Instrument Performance Package (IPP)
    • Technical Jumpstart Program
    • Health Check Program
    • Factory Refresh Program
    • Analyzer Supplies
  • Help/Resources
    • Open Tech Support Ticket
    • Instrument Performance VerificationTM
    • Literature by Application
    • Knowledgebase
    • Application Notes
    • Literature & Publications
    • Datasheets
    • Customer Conference Posters
    • Conference Presentations
    • Webcasts and Webinars
    • Whitepapers
    • Get a Quote
  • Technology
    • Why CRDS
    • What is CRDS
    • Analyzer Performance & Advantages
    • Comparison to Other Trace Gas Analyzers
    • Software Innovation From Picarro
    • Instrument Performance VerificationTM
    • Technical Addendum
    • FAQs
  • Community
    • Picarro Community
    • Knowledgebase
    • Picarro Blog
  • Open Tech Support Ticket
  • Instrument Performance VerificationTM
  • Literature by Application
  • Knowledgebase
  • Application Notes
  • Literature & Publications
  • Datasheets
  • Customer Conference Posters
  • Conference Presentations
  • Webcasts and Webinars
  • Whitepapers
  • Get a Quote

Work at Picarro

Accurate Stable Carbon Isotope Ratio Measurements in Rapidly Varying CO2 Concentrations

Accurate Stable Carbon Isotope Ratio Measurements in Rapidly Varying CO<sub>2</sub> Concentrations
Home › Resources › Whitepapers › Accurate Stable Carbon Isotope Ratio Measurements in Rapidly Varying CO2 Concentrations

Accurate Stable Carbon Isotope Ratio Measurements in Rapidly Varying CO2 Concentrations

Stable carbon isotope analysis relies on the simultaneous or near-simultaneous measurement of two individual species (12C16O2 and13C16O2). In this white paper, we report on improvements that we have made in the G2101-i carbon stable isotope gas analyzer to improve near-simultaneous measurements by more than a factor of eight.

Abstract: 

Stable isotope analysis relies on the simultaneous or near-simultaneous measurement of two individual species. In the case of the Picarro G1101-i and G2101-i gas analyzers, these two species are 12C16O2 and 13C16O2, which we denote 12C and 13C for simplicity. In the G1101-i, alternate measurements of 12C and 13C are made with a period of about eight seconds; the fact that the two gas measurements are not made simultaneously leads to systematic errors in the reported delta in certain conditions when the gas concentration is varying significantly. In this white paper, we report on improvements that we have made in the G2101-i to reduce these systematic errors by more than a factor of eight.

Download Now


  • © 2012 Picarro Inc.
  • Site Map
  • Privacy Policy
  • Terms of Service